MA Journeyman Gas Fitter study guide
MA Journeyman Gas Fitter, administered by Commonwealth of Massachusetts, Division of Occupational Licensure, is mapped here as 5 topic areas; the heaviest are Gas Piping, Equipment & Appliances (56%), Venting (29%) and General Regulations, Inspections & Permits (9%).
About this course: Study gas piping, venting and combustion air with narrated lessons, memory cards and original explained practice.
MA Journeyman Gas Fitter at a glance
- Questions
- 80
- Time allowed
- 200 minutes total (Part I Written 120 minutes + Part II Practical 80 minutes), administered on separate scored parts
- Passing standard
- 70% MINIMUM on EACH part
- Format
- Closed book, computer-based, two independently-scored parts at PSI test centers (Auburn, Boston/Charlestown, Fall River, Lawrence, West Springfield)
- Standard / edition
- Board Candidate Information Bulletin dated 2025-10-03 (current)
- Administered by
- Commonwealth of Massachusetts, Division of Occupational Licensure
Source: Board Candidate Information Bulletin dated 2025-10-03 (current), Commonwealth of Massachusetts, Division of Occupational Licensure. Confirm current details with the exam owner before you book.
Topic areas and weights
| Topic area | Weight | Concepts | Guide |
|---|---|---|---|
| Exam Orientation | 0% | 0 | Section below |
| General Regulations, Inspections & Permits | 9% | 0 | Section below |
| Gas Piping, Equipment & Appliances | 56% | 9 | Section below |
| Venting | 29% | 3 | Section below |
| Combustion, Dilution & Ventilation Air | 6% | 1 | Section below |
Study plan in this course
- The Preflight: Your MA Journeyman Gas Fitter Exam — 5 cards · free
- The Permit Desk: MA Regulations, Inspections & Dig Safe — 6 cards · full course
- The Meter Set to the Appliance: Piping, Sizing, Test & Purge — 16 cards · full course
- Up the Flue: Categories, Type B, Sizing & Spillage — 9 cards · full course
- The Mechanical Room: Combustion Air, Confined vs Unconfined — 5 cards · full course
Exam Orientation
Exam Orientation is one of the 5 areas in this course's MA Journeyman Gas Fitter blueprint. The course teaches it in 1 study unit: The Preflight: Your MA Journeyman Gas Fitter Exam.
Official references for Exam Orientation
- Board of State Examiners of Plumbers & Gas Fitters PSI Candidate Information Bulletin, Journeyman Gas Fitter Part I/II
- PSI Candidate Information Bulletin Reference List
- MGL c.142
- PSI Candidate Information Bulletin Re-examination + Examinations sections
In the app this area comes with 5 memory cards and 5 module-quiz questions and is part of the free starting modules.
General Regulations, Inspections & Permits
General Regulations, Inspections & Permits carries 9% of the MA Journeyman Gas Fitter blueprint used in this course, the third-largest of its 4 weighted areas. The course teaches it in 1 study unit: The Permit Desk: MA Regulations, Inspections & Dig Safe.
Official references for General Regulations, Inspections & Permits
- MGL Chapter: 142
- PSI CIB Reference List
- 248 CMR administrative provisions
- 220 CMR: 99.00
- MGL c.142
- 248 CMR: 11.02
In the app this area comes with 6 memory cards and 6 module-quiz questions in the full course.
Gas Piping, Equipment & Appliances
Gas Piping, Equipment & Appliances carries 56% of the MA Journeyman Gas Fitter blueprint used in this course, the largest of its 4 weighted areas. It spans 9 concepts. The course teaches it in 1 study unit: The Meter Set to the Appliance: Piping, Sizing, Test & Purge.
What Gas Piping, Equipment & Appliances covers
- What must be done to CSST electrically, and with what jumper? — NFPA 54 7.13 CSST bonding
- How does the longest-length method size a gas piping system? — NFPA 54 Chapter 6 Pipe Sizing + capacity tables
- What does a higher-pressure system require? — NFPA 54 Chapter 5/7 pressure regulation & overpressure protection
- Where must an appliance manual shutoff valve be? — NFPA 54 9.6 appliance shutoff valve
- Where does the sediment trap go, and why? — NFPA 54 9.6.2 sediment trap
- How is new gas piping pressure-tested before service? — NFPA 54 8.x pressure testing/inspection
- How and where do you purge gas piping safely? — NFPA 54 8.3 purging
- What Btu threshold moves equipment into the large-equipment rules?
- How is an appliance placed in service and adjusted? — NFPA 54 appliance installation/adjustment
How Gas Piping, Equipment & Appliances connects to other areas
Official references for Gas Piping, Equipment & Appliances
- NFPA 54 Chapter 5 Pipe/Tubing Materials
- NFPA 54 Chapter 6 Pipe Sizing + capacity tables
- NFPA 54 appliance supply pressure
- NFPA 54 Chapter 5/7 pressure regulation & overpressure protection
- NFPA 54 9.6 appliance shutoff valve
- NFPA 54 9.6.2 sediment trap
- NFPA 54 9.6 appliance/flexible connectors
- NFPA 54 8.3 purging
- NFPA 54 7.2 piping installation - prohibited locations
- NFPA 54 7.1 underground piping
- NFPA 54 appliance installation/adjustment
- NFPA 54 5.6 copper/brass tubing
In the app this area comes with 16 memory cards and 38 module-quiz questions in the full course.
Venting
Venting carries 29% of the MA Journeyman Gas Fitter blueprint used in this course, the second-largest of its 4 weighted areas. It spans 3 concepts. The course teaches it in 1 study unit: Up the Flue: Categories, Type B, Sizing & Spillage.
What Venting covers
- What are the four appliance venting categories? — NFPA 54 12.x appliance venting categories
- How are vents and chimneys sized? — NFPA 54 Chapter 13 venting tables
- What do vent terminations have to clear? — NFPA 54 12.x vent termination clearances
How Venting connects to other areas
- What are the four appliance venting categories? links to How is an appliance placed in service and adjusted? — Gas Piping, Equipment & Appliances
Official references for Venting
- NFPA 54 12.x appliance venting categories
- NFPA 54 12.x natural draft venting
- NFPA 54 vent materials
- NFPA 54 13.x vent connector rise/length
- NFPA 54 12.x masonry chimney requirements
- NFPA 54 draft hood/relief opening
- NFPA 54 Chapter 13 venting tables
- NFPA 54 13.x common venting
- NFPA 54 12.x vent termination clearances
In the app this area comes with 9 memory cards and 19 module-quiz questions in the full course.
Combustion, Dilution & Ventilation Air
Combustion, Dilution & Ventilation Air carries 6% of the MA Journeyman Gas Fitter blueprint used in this course, the 4th-largest of its 4 weighted areas. It spans 1 concept. The course teaches it in 1 study unit: The Mechanical Room: Combustion Air, Confined vs Unconfined.
What Combustion, Dilution & Ventilation Air covers
- How do you size all-indoor-air combustion openings? — NFPA 54 9.3.2 indoor combustion air
Official references for Combustion, Dilution & Ventilation Air
- NFPA 54 9.3 air for combustion and ventilation
- NFPA 54: 9.3, 9.3.3
- NFPA 54 9.3.3 outdoor combustion air openings
- NFPA 54 9.3.2 indoor combustion air
In the app this area comes with 5 memory cards and 5 module-quiz questions in the full course.
Official references
- Board of State Examiners of Plumbers & Gas Fitters PSI Candidate Information Bulletin, Journeyman Gas Fitter Part I/II
- PSI Candidate Information Bulletin Reference List
- MGL c.142
- PSI Candidate Information Bulletin Re-examination + Examinations sections
- MGL Chapter: 142
- PSI CIB Reference List
- 248 CMR administrative provisions
- 220 CMR: 99.00
- 248 CMR: 11.02
- PSI Candidate Information Bulletin, Board of State Examiners of Plumbers & Gas Fitters, dated: 2025-10-03
- Mass.gov
- 248 CMR 3.00/4.00/5.00/6.00/7.00/10.00/11.00 + MGL Chapter: 142
- NFPA 54 Chapter 5 Pipe/Tubing Materials
- NFPA 54 Chapter 6 Pipe Sizing + capacity tables
- NFPA 54 appliance supply pressure
- NFPA 54 Chapter 5/7 pressure regulation & overpressure protection