Pass Plumbing Exam

MA Journeyman Gas Fitter study guide

MA Journeyman Gas Fitter, administered by Commonwealth of Massachusetts, Division of Occupational Licensure, is mapped here as 5 topic areas; the heaviest are Gas Piping, Equipment & Appliances (56%), Venting (29%) and General Regulations, Inspections & Permits (9%).

About this course: Study gas piping, venting and combustion air with narrated lessons, memory cards and original explained practice.

MA Journeyman Gas Fitter at a glance

Questions
80
Time allowed
200 minutes total (Part I Written 120 minutes + Part II Practical 80 minutes), administered on separate scored parts
Passing standard
70% MINIMUM on EACH part
Format
Closed book, computer-based, two independently-scored parts at PSI test centers (Auburn, Boston/Charlestown, Fall River, Lawrence, West Springfield)
Standard / edition
Board Candidate Information Bulletin dated 2025-10-03 (current)
Administered by
Commonwealth of Massachusetts, Division of Occupational Licensure

Source: Board Candidate Information Bulletin dated 2025-10-03 (current), Commonwealth of Massachusetts, Division of Occupational Licensure. Confirm current details with the exam owner before you book.

Topic areas and weights

Topic areaWeightConceptsGuide
Exam Orientation0%0Section below
General Regulations, Inspections & Permits9%0Section below
Gas Piping, Equipment & Appliances56%9Section below
Venting29%3Section below
Combustion, Dilution & Ventilation Air6%1Section below

Study plan in this course

  1. The Preflight: Your MA Journeyman Gas Fitter Exam — 5 cards · free
  2. The Permit Desk: MA Regulations, Inspections & Dig Safe — 6 cards · full course
  3. The Meter Set to the Appliance: Piping, Sizing, Test & Purge — 16 cards · full course
  4. Up the Flue: Categories, Type B, Sizing & Spillage — 9 cards · full course
  5. The Mechanical Room: Combustion Air, Confined vs Unconfined — 5 cards · full course

Exam Orientation

Exam Orientation is one of the 5 areas in this course's MA Journeyman Gas Fitter blueprint. The course teaches it in 1 study unit: The Preflight: Your MA Journeyman Gas Fitter Exam.

Official references for Exam Orientation

  • Board of State Examiners of Plumbers & Gas Fitters PSI Candidate Information Bulletin, Journeyman Gas Fitter Part I/II
  • PSI Candidate Information Bulletin Reference List
  • MGL c.142
  • PSI Candidate Information Bulletin Re-examination + Examinations sections

In the app this area comes with 5 memory cards and 5 module-quiz questions and is part of the free starting modules.

General Regulations, Inspections & Permits

General Regulations, Inspections & Permits carries 9% of the MA Journeyman Gas Fitter blueprint used in this course, the third-largest of its 4 weighted areas. The course teaches it in 1 study unit: The Permit Desk: MA Regulations, Inspections & Dig Safe.

Official references for General Regulations, Inspections & Permits

  • MGL Chapter: 142
  • PSI CIB Reference List
  • 248 CMR administrative provisions
  • 220 CMR: 99.00
  • MGL c.142
  • 248 CMR: 11.02

In the app this area comes with 6 memory cards and 6 module-quiz questions in the full course.

Gas Piping, Equipment & Appliances

Gas Piping, Equipment & Appliances carries 56% of the MA Journeyman Gas Fitter blueprint used in this course, the largest of its 4 weighted areas. It spans 9 concepts. The course teaches it in 1 study unit: The Meter Set to the Appliance: Piping, Sizing, Test & Purge.

What Gas Piping, Equipment & Appliances covers

  • What must be done to CSST electrically, and with what jumper? — NFPA 54 7.13 CSST bonding
  • How does the longest-length method size a gas piping system? — NFPA 54 Chapter 6 Pipe Sizing + capacity tables
  • What does a higher-pressure system require? — NFPA 54 Chapter 5/7 pressure regulation & overpressure protection
  • Where must an appliance manual shutoff valve be? — NFPA 54 9.6 appliance shutoff valve
  • Where does the sediment trap go, and why? — NFPA 54 9.6.2 sediment trap
  • How is new gas piping pressure-tested before service? — NFPA 54 8.x pressure testing/inspection
  • How and where do you purge gas piping safely? — NFPA 54 8.3 purging
  • What Btu threshold moves equipment into the large-equipment rules?
  • How is an appliance placed in service and adjusted? — NFPA 54 appliance installation/adjustment

How Gas Piping, Equipment & Appliances connects to other areas

Official references for Gas Piping, Equipment & Appliances

  • NFPA 54 Chapter 5 Pipe/Tubing Materials
  • NFPA 54 Chapter 6 Pipe Sizing + capacity tables
  • NFPA 54 appliance supply pressure
  • NFPA 54 Chapter 5/7 pressure regulation & overpressure protection
  • NFPA 54 9.6 appliance shutoff valve
  • NFPA 54 9.6.2 sediment trap
  • NFPA 54 9.6 appliance/flexible connectors
  • NFPA 54 8.3 purging
  • NFPA 54 7.2 piping installation - prohibited locations
  • NFPA 54 7.1 underground piping
  • NFPA 54 appliance installation/adjustment
  • NFPA 54 5.6 copper/brass tubing

In the app this area comes with 16 memory cards and 38 module-quiz questions in the full course.

Venting

Venting carries 29% of the MA Journeyman Gas Fitter blueprint used in this course, the second-largest of its 4 weighted areas. It spans 3 concepts. The course teaches it in 1 study unit: Up the Flue: Categories, Type B, Sizing & Spillage.

What Venting covers

  • What are the four appliance venting categories? — NFPA 54 12.x appliance venting categories
  • How are vents and chimneys sized? — NFPA 54 Chapter 13 venting tables
  • What do vent terminations have to clear? — NFPA 54 12.x vent termination clearances

How Venting connects to other areas

Official references for Venting

  • NFPA 54 12.x appliance venting categories
  • NFPA 54 12.x natural draft venting
  • NFPA 54 vent materials
  • NFPA 54 13.x vent connector rise/length
  • NFPA 54 12.x masonry chimney requirements
  • NFPA 54 draft hood/relief opening
  • NFPA 54 Chapter 13 venting tables
  • NFPA 54 13.x common venting
  • NFPA 54 12.x vent termination clearances

In the app this area comes with 9 memory cards and 19 module-quiz questions in the full course.

Combustion, Dilution & Ventilation Air

Combustion, Dilution & Ventilation Air carries 6% of the MA Journeyman Gas Fitter blueprint used in this course, the 4th-largest of its 4 weighted areas. It spans 1 concept. The course teaches it in 1 study unit: The Mechanical Room: Combustion Air, Confined vs Unconfined.

What Combustion, Dilution & Ventilation Air covers

  • How do you size all-indoor-air combustion openings? — NFPA 54 9.3.2 indoor combustion air

Official references for Combustion, Dilution & Ventilation Air

  • NFPA 54 9.3 air for combustion and ventilation
  • NFPA 54: 9.3, 9.3.3
  • NFPA 54 9.3.3 outdoor combustion air openings
  • NFPA 54 9.3.2 indoor combustion air

In the app this area comes with 5 memory cards and 5 module-quiz questions in the full course.

Official references

  • Board of State Examiners of Plumbers & Gas Fitters PSI Candidate Information Bulletin, Journeyman Gas Fitter Part I/II
  • PSI Candidate Information Bulletin Reference List
  • MGL c.142
  • PSI Candidate Information Bulletin Re-examination + Examinations sections
  • MGL Chapter: 142
  • PSI CIB Reference List
  • 248 CMR administrative provisions
  • 220 CMR: 99.00
  • 248 CMR: 11.02
  • PSI Candidate Information Bulletin, Board of State Examiners of Plumbers & Gas Fitters, dated: 2025-10-03
  • Mass.gov
  • 248 CMR 3.00/4.00/5.00/6.00/7.00/10.00/11.00 + MGL Chapter: 142
  • NFPA 54 Chapter 5 Pipe/Tubing Materials
  • NFPA 54 Chapter 6 Pipe Sizing + capacity tables
  • NFPA 54 appliance supply pressure
  • NFPA 54 Chapter 5/7 pressure regulation & overpressure protection

Start the free MA Journeyman Gas Fitter modules → · Pricing · FAQ